CLIENT: Synthomer

Osmosis plant sized to ensure maximum water production

 

IDRO Group took care of sizing the osmosis system to ensure maximum water production at 25 cubic meters/h. This osmosis system has been sized for a supply flow rate of 36 mc / h and a permeation efficiency of 70%.

The osmosis unit has been set up with a double pressurization pump to have a redundancy that guarantees immediate continuity of operation in the event of a failure of one of the machines. 

To ensure a hardness value close to 0 in the treatment chain, a DUPLEX softening unit with two redundant columns downstream of the osmotic modules. 

Finally, an intermediate passage tank has been prepared from which the osmotic water is released to the softening unit with a double redundant pump. 

The plant is able to achieve excellent levels of output water quality
The wastewater is also suitable for discharge into surface water but the ideal destination is still reuse in the plant where possible.

Location: Filago (BG) Italia

Client: Synthomer (BG) Leading Company in the Chemical Industry and Aqueous Polymers

Project type: Turnkey project for design, construction, installation and commissioning on site.

Water treatment plant: Osmosis Water Treatment Plant

Raw water source: Water from a well

Treatment water quality: Water suitable for reuse in groundwater or in the production cycle.

Capacity: 25 mc/h of water